Created: | 06.07.2011 15:17:10 |
Modified: | 12.10.2012 15:26:51 |
![]() |
|
![]() |
Attribute | Details |
public Code FireProtectionClass |
<<BCC>>Range:0 to 1definition=The code specifying the fire protection class of this external building protection. dictionaryEntryName=External Building Protection. Fire Protection Class. Code sequencingKey=1 uniqueIdentifier=UN00004052 versionIdentifier=1.0 |
public Code HydrantType |
<<BCC>>Range:0 to 1definition=The code specifying the type of hydrant or water source, such as standard hydrant, standpipe, pond or tanker, that provides external building protection. dictionaryEntryName=External Building Protection. Hydrant Type. Code sequencingKey=5 uniqueIdentifier=UN00004056 versionIdentifier=1.0 |
public Text HydrantTypeDescription |
<<BCC>>Range:0 to 1definition=The textual description of the type of hydrant that provides external building protection. dictionaryEntryName=External Building Protection. Hydrant Type Description. Text sequencingKey=6 uniqueIdentifier=UN00004057 versionIdentifier=1.0 |
public Measure NearestFireStationDistance |
<<BCC>>Range:0 to 1definition=The measure of the distance from the building to the nearest fire station that provides external building protection. dictionaryEntryName=External Building Protection. Nearest Fire Station Distance. Measure sequencingKey=4 uniqueIdentifier=UN00004055 versionIdentifier=1.0 |
public Measure NearestHydrantDistance |
<<BCC>>Range:0 to 1definition=The measure of the distance from the building to the nearest hydrant that provides external building protection. dictionaryEntryName=External Building Protection. Nearest Hydrant Distance. Measure sequencingKey=7 uniqueIdentifier=UN00004058 versionIdentifier=1.0 |
public Measure NearestPoliceStationDistance |
<<BCC>>Range:0 to 1definition=The measure of the distance from the building to the nearest police station that provides external building protection. dictionaryEntryName=External Building Protection. Nearest Police Station Distance. Measure sequencingKey=8 uniqueIdentifier=UN00004059 versionIdentifier=1.0 |
public Text PrivateFireStationName |
<<BCC>>Range:0 to 1definition=The name, expressed as text, of the private fire station that provides external building protection. dictionaryEntryName=External Building Protection. Private Fire Station Name. Text sequencingKey=3 uniqueIdentifier=UN00004054 versionIdentifier=1.0 |
public Text PublicFireStationName |
<<BCC>>Range:0 to 1definition=The name, expressed as text, of the public fire station that provides external building protection. dictionaryEntryName=External Building Protection. Public Fire Station Name. Text sequencingKey=2 uniqueIdentifier=UN00004053 versionIdentifier=1.0 |
Element | Source Role | Target Role | Details |
«ACC» BuildingInsuranceFactor Class «ASCC» |
Name: |
Name: Specified |
Tag | Value | Details |
definition | The protection, by external means, that a building has against a threat, such as fire. | |
dictionaryEntryName | ExternalBuildingProtection. Details | |
uniqueIdentifier | UN00004051 | |
versionIdentifier | 1.0 |